- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
起搏心电图的解读及异常情况处PPT课件
* CorePace Module 4: Troubleshooting An intrinsic depolarization occurs in the atrium, but this depolarization is not sensed by the pacemaker. Therefore, the pacemaker sends an inappropriate pacing pulse to that chamber. Undersensing can be thought of as 搊verpacing. In this example, an AAI pacemaker is programmed to inhibit the atrial pacing pulse when a P-wave is sensed. Because the P-wave was not sensed, the pacemaker delivered an atrial pulse. If a pacemaker is undersensing, you will not see appropriate atrial sense markers on the marker channel. * CorePace Module 4: Troubleshooting Insulation breaks may cause undersensing if the insulation break results in the: Reduction of intrinsic beats at the sense amplifier Inability of the amplitude to meet the sensitivity requirement Conductor fracture may cause an open circuit. If intrinsic signals cannot cross the conductor fracture, undersensing will occur. The primary cause of conductor fracture is the chronic stress imposed on the lead as a result of its placement in the subclavian region, and may be reflected in increased impedance readings. During lead maturation, the pacemaker抯 sensitivity may be decreased 20?0%. (Steroid-eluting leads may eliminate the reduction in sensitivity by minimizing the growth of fibrotic tissue near the electrode). Lead dislodgment usually occurs early in the life of the pacemaker before the lead has fibrosed to endocardial tissue. The primary causes of lead dislodgment are: Inadequate initial positioning Patient movement (bringing arms overhead, etc.) Lead dislodgment occurs in approximately 2?% of pacemaker implants. Changes in the native signal may be caused by: Myocardial infarction Change in medications (not common) Electrolyte imbalance Undersensing may be caused by an inappropriately programmed setting. * CorePace Module 4: Troubleshooting If a pacemaker is oversensing, you will see signals on the marker channel that do not correspond to the ECG pattern. In this example,
文档评论(0)