Effect of perfect anatomic repair, imperfect anatomic repair, and no repair of a 25% Hill-Sachs lesion on bony contact and capsular forces at the glenohumeral joint.pdfVIP
- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Effect of perfect anatomic repair, imperfect anatomic repair, and no repair of a 25% Hill-Sachs lesion on bony contact and capsular forces at the glenohumeral joint.pdf
ORTHTR 10906 No. of Pages 8
Orthopaedics Traanud matology
ORIGINAL PAPER
Sports Orthop. Traumatol. xx, xx–xx (2016) C Elsevier GmbH
www.SOT /10.1016/j.orthtr.2016.12.002
Summary
Background: To compare the impact of a 25% Hill-Sachs lesion (defect condition, D) and perfect and imperfect anatomic repairs (PAR and IAR) of such lesions on glenohumeral bony contact and capsular forces in response to compressive and anterior loads. Material and methods: A robotic/universal force-moment sensor testing system applied joint compression (22 N) and an anterior load (44 N) to cadaveric shoulders (n = 9) at three glenohumeral joint positions (abduction/external rotation): 08/08, 308/308, and 608/608. The 25% bony defect state, PAR state, and IAR state were created and the loading protocol was performed. Bony contact/capsular forces were measured in each position for each shoulder state. Results: PAR had the least biomechanical impact on the bony surfaces and capsule of the glenohumeral joint. D had less impact on the bones and capsule compared to the IAR. The bony surfaces and capsule of the glenohumeral joint sustained the greatest forces in the IAR condition. Conclusions: The PAR state had the least force applied to the bony surfaces and capsule of the glenohumeral joint. The defect shoulder had signi?cantly less force applied to the bones and capsule of the glenohumeral joint compared to the IAR (greatest force applied). Performing an osteoallograft repair that does not fully restore normal anatomy may result in abnormal bony contact/capsular forces, resulting in joint wear, arthritis, and injury to the surrounding capsule. Clinical relevance: The importance of performing an osteoallograft repair of a Hill-Sachs defect that closely matches the pre-injury state and restores normal humeral head anatomy.
Keywords Shoulder – Hill-Sachs lesion – Glenohumeral joint – Bony contact – Capsular force
N.K. Bakshi et al.
Ein?uss einer perfekten anatomischen Rekonstruktion, mangelhaften
您可能关注的文档
- Deflation rate dependence of receding contact angle on polymeric surfaces.pdf
- Deglutition-Induced Atrial Tachycardia Localised with Contact Force-Guided Activation Mapping.pdf
- Delamination mechanism maps for coatingssubstrates system subjected to adhesive contact loads.pdf
- DEM simulation of bonded granular material. Part I Contact model and application to cemented sand.pdf
- DEM study to determine the relationship between particle velocity fluctuations and contact force disappearance.pdf
- DEM-CFD analysis of contact electrification and electrostatic interactions during fluidization.pdf
- Demand for bear viewing hikes Implications for balancing visitor satisfaction with safety in protected areas.pdf
- Dendritic cells' death induced by contact sensitizers is controlled by Nrf2 and depends on glutathione levels.pdf
- Depletion of λ-DNA near moving contact line.pdf
- Depth of field synthesis from sparse views.pdf
- Effect of possible rotor deformation on the probability of face contact for a liquid film bearing.pdf
- Effect of race conformities in angular contact ball bearing.pdf
- Effect of rapid thermal annealing on the Mo back contact properties for Cu2ZnSnSe4 solar cells.pdf
- Effect of strengthening phase on material transfer behavior of Ag-based contact materials under different voltages.pdf
- Effect of swabbing techniques on the efficiency of bacterial recovery from food contact surfaces.pdf
- Effect of Tabor parameter on hysteresis losses during adhesive contact.pdf
- Effect of the operating parameters on second scale time correlation between lines of the same element using axially viewed inductively coupled plasma-multichannel-based emission spectrometry.pdf
- Effect of the osmolarity change in multipurpose solutions induced by an improper contact lens case cleaning procedure.pdf
- Effect of thermal and load cycle on thermal contact conductance across dissimilar joints at cryogenic temperature.pdf
- Effect of thickness and boundary conditions on the behavior of viscoelastic layers in sliding contact with wavy profiles.pdf
文档评论(0)