Effect of the operating parameters on second scale time correlation between lines of the same element using axially viewed inductively coupled plasma-multichannel-based emission spectrometry.pdfVIP

Effect of the operating parameters on second scale time correlation between lines of the same element using axially viewed inductively coupled plasma-multichannel-based emission spectrometry.pdf

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Effect of the operating parameters on second scale time correlation between lines of the same element using axially viewed inductively coupled plasma-multichannel-based emission spectrometry.pdf

Spectrochimica Acta Part B 55 ?2000. 1431?1450 Effect of the operating parameters on second scale time correlation between lines of the same element using axially viewed inductively coupled plasma-multichannel-based emission spectrometry M. Chausseau, E. Poussel, J.M. MermetU Laboratoire des Sciences Analytiques, Uni¨ersit′e Claude Bernard?Lyon 1, F-69622, Villeurbanne Cedex, France Received 7 April 2000; accepted 9 June 2000 Abstract The in?uence of power and carrier gas ?ow rate on time correlation between lines of the same element was studied, using simultaneous measurements with multichannel detection and axially viewed ICP-AES. Both correlation between lines and improvements in the R.S.D. values were calculated to evaluate the link between correlated signals and improved R.S.D. values but also to have a look at the in?uence of the magnitude of the relative ?uctuations of the signals. A dual-view Optima 3000 ICP system was used to permit the simultaneous determination of atomic and ionic lines of nine elements on a wide range of energy. Under suitable conditions, quite good correlations were observed between lines, providing improvements in the repeatability of the signals, regardless of the nature of these lines. Particular behaviors were found for atomic lines of excitation energies higher than 5 eV, for the correlation between the Mg 202.582 nm atomic line and each Mg ionic line and also for Sr lines. Magnitudes of the relative ?uctuations of the lines have shown to play a major role both on the correlation and on the improvement in the R.S.D. values. Differences of more than 15% in the magnitude of the relative ?uctuations of the two signals will lead to a degradation of the correlation, causing a decrease of the improvement in the repeatability. A decrease of the improvement was observed even if the correlation between lines was not affected. ? 2000 Elsevier Science B.V. All rights reserved. Keywords: Inductively coupled plasma-atomic emission spectrometry;

您可能关注的文档

文档评论(0)

2752433145 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档