电磁炉断续加热(Intermittent heating of induction cooker).docVIP

电磁炉断续加热(Intermittent heating of induction cooker).doc

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
电磁炉断续加热(Intermittent heating of induction cooker) Induction cooker, intermittent heating, Ye Quanlin, -[2008-07-01] [from, my article] read: 3 -------------------------------------------------------------------------------- When the electromagnetic oven intermittent heating fault, the fault coverage for the general: the main power rectifier +305V power supply circuit, current detection circuit, circuit voltage comparison circuit, and electromagnetic furnace control circuit and other components damaged. At the same time, consideration should be given to customers in the use of the electromagnetic oven, due to excessive force to start switch, the control circuit board solder sealing off, or cause circuit damage. All of them lead to the above faults. Maintenance method Under the condition of fittings, it can be replaced by the control panel first. If the test machine is normal, the control panel is damaged and should be repaired or replaced. If the trouble has not been removed after the test of the induction cooker, the fault shall be maintained or replaced on the main circuit board. In order to distinguish and reduce the potential range of failure, in order to save the maintenance time and improve the quality of maintenance, the above alternative methods are used instead of maintenance. Maintenance of power supply circuit; The DC voltage of the rectifier bridge is normal to the ground +305V voltage by using the 500 type three meter DC voltage 500V gear. When the voltage is low to +205V, the capacitor is generally considered to be C4 (5 F/275V) failure or open circuit. If the positive resistance of the rectifier bridge becomes larger or fails, the intermittent heating fault occurs in the induction cooker. Troubleshooting after replacement of damaged components. Two 、 maintenance of current detection circuit; The first 500 three meter resistance 100 ohm, road detection in CT1 current transformer (WX22006A) secondary winding resistance value is normal 300, if less than 3

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档