如何提高继电保护(How to improve relay protection).docVIP

如何提高继电保护(How to improve relay protection).doc

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
如何提高继电保护(How to improve relay protection)

如何提高继电保护(How to improve relay protection) Abstract: This paper summarizes the common causes of accidents, and classifies the types of accidents. Combined with the actual situation, the basic ideas and methods of analyzing and dealing with the general microcomputer relay protection accidents are put forward. Key words: relay protection; accident; treatment method 1 types of relay protection accidents 1.1 fixed value problem 1. The error of setting calculation II. Human setting error; device setting drift; a components aging and damage; B temperature and humidity influence; C fixed value drift problem 1.2 、 power supply problems: inverter voltage stabilized power supply, a ripple factor is too high, B output power is insufficient or stability is poor 1.3 TA saturation as the pivotal measure of relay protection TA two system, with the system short-circuit current increases rapidly, in the low pressure system of current transformer saturation has become increasingly prominent, has affected the correct action of relay protection device. W editor. Because the feeder protection is refused because of the saturation of the current transformer, the accident of the three switch of the main transformer and the main switch of the main transformer is happened. Due to the digital relay controlled by microcomputer, the main power supply is only about 5V, the effective range of the data acquisition part of the level is only about 10V, so it can effectively handle the signal range is smaller and the influence of current transformer saturation on digital relay will be greater. The influence on the auxiliary criterion (II) the influence of the algorithm based on the power frequency component, the influence on the different data acquisition methods, and the methods and Countermeasures to prevent the TA saturation. 1.4, the operation experience of anti-jamming shows that the anti-interference performance of microprocessor-based protection is poor, and the use of walkie talkie and other w

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档