Control of Power Inverters in Renewable Energy and Smart Grid Integration电力—ch20.pdf

Control of Power Inverters in Renewable Energy and Smart Grid Integration电力—ch20.pdf

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
电工电子,电器,安装,维修,电磁炉,线路图,电路图,元器件,监测,故障,电气,PID

20 Robust Droop Control with Improved Voltage Quality In Chapter 19, a robust droop controller is presented to achieve accurate sharing of both real power and reactive power for different types of inverters while maintaining excellent capability of voltage regulation. Apart from C-inverters, the THD of the output voltage is high when the load is non-linear. In this chapter, the strategy described in Chapter 8 is combined with the robust droop controller to improve the voltage quality. As a result, all the three major problems associated with the parallel operation of inverters, that is, sharing accuracy, voltage regulation and voltage THD, are solved with a compact controller. Experimental results are provided to verify the analysis and design. In this chapter, R-inverters are taken as an example but the concept can be extended to L- and C-inverters. 20.1 Control Strategy For a single-phase inverter depicted in Figure 20.1, the controller presented in Chapter 8, as shown in Figure 20.2(a), is able to bypass the harmonic components in the load current and hence the output voltage THD is low even when the load is non-linear. It consists of a proportional feedback of the inductor current (Zhong 2012c), which is also widely referred to as a virtual resistor (Dahono 2003, 2004; Dahono et al. 2001; Li 2009) to dampen the resonance of the LC filter. The output impedance of the inverter is forced to be predominantly resistive with a large enough K i . In addition to the current feedback through the virtual resistor K i , the voltage error vr − vo is added to vr through a block KR (s), which is able to reduce the output impedance of the inverter at harmonic frequencies. As a result, the high voltage THD caused by a large K i when nonlinear loads are present is reduced. The block KR (s) in Figure 20.2(a) can be chosen as the resonant harmonic compensators (Castilla et al. 2009; Shen et al. 2010)

您可能关注的文档

文档评论(0)

masterchief216 + 关注
实名认证
内容提供者

该用户很懒,什么也没介绍

版权声明书
用户编号:5114101340000003

1亿VIP精品文档

相关文档