商场空调(Mall air conditioner) Mall air conditioner 2006-3-13 Construction unit: Xiong Gu group (Shenzhen) Co., Ltd. Location: Shenzhen Caiwuwei Design time: 1993.9 United States Architectural Design Co., Ltd. Hongkong branch consultants engineering company The second Design Institute of Shenzhen Architectural Design Institute Construction time: 1994.10-1996.6 Gross floor area: the gross floor area is about 278610M2 Height: basement two, office tower sixty-nine, high 383.95m; apartment tower thirty-three, high 120.50m. Office building standard height 3.75m, apartment standard height 3.0m. Function overview: the basement two floors, respectively, car pool, pool, water pump room, power distribution room; apartment building part to five layers for the podium, respectively with shopping malls, restaurants, banks, six to thirty-three layers of suite style apartments; office buildings and apartment buildings to a high degree of the corresponding part of the five podium as the overhead layer is arranged in the middle of the two Ge layer, the first layer (overhead layer on the first layer) to sixty-nine layers for large bay buildings. Ventilation design overview Note: three air supply systems are installed on each floor of the underground car park, located in the middle of the garage. All imports of fans. In addition, due to the design of only air injection, no models and other parameters, it can not find the power term. Smoke control design Note: 1. Underground parking garage: The automatic fire equipment; Divided into the fire area of not more than 2000m2; Divided into the smoke prevention area of no more than 500 m2, each smoke prevention area has 800mm high smoke screen and independent smoke exhaust system. 2. corridor smoke evacuation: Each corridor is divided into two smoke prevention zones, each area is provided with a smoke exhaust shaft, and an electric smoke exhaust port 600*1200 is arranged, located in the middle part of the inner corridor. Each vertical shaft of smo

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档