电缆载流量的计算(Calculation of ampacity of cables).docVIP

电缆载流量的计算(Calculation of ampacity of cables).doc

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
电缆载流量的计算(Calculation of ampacity of cables) Ampacity of cable: The current carrying capacity of cable is a cable line in the current transmission power when the heat, in stable condition, when the working temperature of cable conductor cable to allow long called the cable ampacity Ampacity for long time. The estimation formula of two point five multiplied by nine, to go up by a smooth number. Thirty-five by three point five, both in group minus five points. Conditions have changed and converted, high temperature ten percent off copper upgrade. Intubation root number two three four, 87 forty percent off full flow. That (1) this section formulas for various insulated wire (rubber and plastic insulated wire) ampacity (safe current) is not directly pointed out, but the section multiplied by a certain multiple to that obtained by mental arithmetic. As can be seen from table 53, the multiples decrease with the increase of the cross section. Two point five times multiplied by nine, go up to reduce a number to go, that is 2.5mm and the following sections of aluminum core insulation line, its carrying capacity is about 9 times the number of sections. For example 2.5mm lead, the ampacity is 2.5 x 9 = 22.5 (A). The relationship between the current carrying capacity and the cross sectional number of the wires from 4mm and above is along the line number, and the multiples are progressively reduced by L, i.e., 4 * 8, 6 * 7, 10 * 6, 16 * 5, 25 * 4. Thirty-five multiplied by three point five, both in group minus five points, said 35mm, the lead carrying capacity is 3.5 times the cross section number, that is, 35 x 3.5 = 122.5 (A). From 50mm and above, the relationship between the carrying capacity and the number of sections becomes two, the two line numbers are in one group, and the multiples are reduced by 0.5 sequentially. That is to say, the carrying capacity of 50 and 70mm wires is 3 times of the cross section; the carrying capacity of 95 and 120mm wires is 2.5 times of the cro

您可能关注的文档

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档