扫描电镜与投射电镜(Scanning electron microscopy and projection electron microscopy).docVIP

扫描电镜与投射电镜(Scanning electron microscopy and projection electron microscopy).doc

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
扫描电镜与投射电镜(Scanning electron microscopy and projection electron microscopy)

扫描电镜与投射电镜(Scanning electron microscopy and projection electron microscopy) 1) detector X ray spectrometer WDS The principle is basically the same as the X-ray fluorometer, but using electrons instead of x-rays as the source of the shock. The X-ray spectrometer is characterized by high resolution, usually 5-10ev, and can work at room temperature, so the accuracy of the analysis is high and the test limit is low. In addition, according to the Bragg theorem 2dsin theta = lambda, the crystal of crystal spacing d is used to analyze the light elements, such as boron, carbon, nitrogen and oxygen, which identify the wavelength of X ray. However, the X-ray spectrometer has its limitations, and its spectral crystal accepts X rays with low cubiage, and the X-ray utilization is low. In addition, the sample requires the surface to be smooth and clean like gold samples, and cannot analyze the uneven samples. The principle EDS for lithium drift silicon detector When the photon enters the detector, a certain number of electron hole pairs are excited in the Si (Li) crystal. The lowest average energy epsilon that produces a hole is certain, so the number of holes caused by an X-ray photon is equal to delta E/epsilon. The higher the energy of the incident X-ray photon, the greater the N. By using the bias on both ends of the crystal to collect the electron hole pairs, the preamplifier is converted to the current pulse, and the height of the current pulse depends on the size of N. Current pulse through the main amplifier converts voltage pulse into the multi-channel pulse height analyzer, pulse height analyzer according to height to classify the pulse count, so we can trace a X-ray energy size distribution map. Analysis features of EDS spectrometer: The spectrometer detects X-ray efficiency. At the same time to analyze all the elements within the X-ray photon energy measuring and counting, qualitative analysis results can be obtained in a few minutes, the spectrometer can measure each

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档