- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
手算钢筋量(Manual reinforcement)
手算钢筋量(Manual reinforcement) Celestial cad - the file layout - the bulk of the old - first the old drawing - then the old drawing is placed in the location - and then its converted to the third version of the sky - and then autocad and the mini look GJZ construction of the KZ frame pillar KZZ frame pillar XZ core column LZ beam column QZ to build the wall column GZ constructional column YDZ constrained edge pillar; YAZ constrained edge dark column; YYZ constraints edge wall injection; YJZ constrains the edge of the Angle. GDZ structure edge end column; GAZ constructs the edge of the dark column; GYZ structure edge wall injection; GJZ construction edge Angle wall column; AZ nonmarginal dark column; FBZ support wall column; LL even beam; AL dark beam; BKL frame beam; JD held a hole; YD round hole 1. When the upper longitudinal tendon is redundant, use the oblique line: / to separate the longitudinal bars from top to bottom. Eg: 6 Φ 25 4/2 said on the upper reinforcement for 4 Φ 25, discharge of 2 Φ 25. 2. When there are two diameters of the longitudinal bar, the two diameters are connected with the plus sign +, and the angular part is written in the front Eg: 2 + 2 Φ Φ 22 22 said only a row of steel bar, two in the corner, two in the middle, even decorate. 3. The brace is written in brackets after the plus sign Eg: 2 Φ 22 + 2 (4 Φ 12) said Φ 22 for long, 4 phi 12 tud, used for six leg strapped. 4: when the lower part of the beam is not extended into the pedestal, the numerical value of the lower longitudinal tendon of the beam support is written in brackets Eg: the lower part of beam longitudinal reinforcement to label is 6 Φ 25 (2) / 2 and 4, longitudinal reinforcement to 2 on the said Φ 25, and not into the pedestal; Under a row of longitudinal reinforcement is 4 Φ 25, all into the bearing. The length of the curve of 180 degrees is 6.25d The length of the Angle of the 135 degree Angle is 11.9 d The 90-degree straight hook takes 3.5 d The 45-degree Angle hook is taken
您可能关注的文档
- 工程概预算与招投标第二阶段在线作业(The project budget and bidding for the second phase of online operation).doc
- 工程测量学(Engineering surveying).doc
- 工程测量期末考试卷及答案(Final examination paper and answer).doc
- 工程测量论文(Engineering surveying paper).doc
- 工程测量(Engineering surveying).doc
- 工程测量员-RTK测高试验与精度分析(Engineering surveyor - RTK test and precision analysis).doc
- 工程现场文明及安全施工标准(Engineering site civilization and safety construction standard).doc
- 工程经济课后答案(After-school answers to engineering economics).doc
- 工程经济6(Engineering economy 6).doc
- 工程测量试卷A卷期末试题(Project A book A final exam).doc
- 打磨82项优秀用车习惯(Polish 82 excellent car habits).doc
- 打赢没有资源的战争管理(Win the war management without resources).doc
- 打造CBTC系统 工业级(DCS)数据承载网解决方案(Build CBTC system industrial class (DCS) data bearing network solution).doc
- 打造优秀红豆企业文化(Make excellent red bean culture).doc
- 打造安全沙盘系统(Create a safe sand disk system).doc
- 托业词汇汇总(Summary of toeic vocabulary).doc
- 我重温了几部经典的爱国主义电影(I revisited some classic patriotic films).doc
- 托福top105心得(Toefl top105).doc
- 扬子空调故障代码(The fault code of the Yangtze air conditioner).doc
- 扶壁式挡土墙计算实例(Calculation example of retaining wall retaining wall).doc
文档评论(0)