Creep modeling for concrete-filled steel tubes
Journal of Constructional Steel Research 59 (2003) 1327–1344
/locate/jcsr
Creep modeling for concrete-filled steel tubes
Wassim Naguib
a
, Amir Mirmiran
b,?
a
Simpson, Gumpertz Heger Inc., 222 Sutter Street, Suite 300, San Francisco, CA 94108, USA
b
North Carolina State University, Department of Civil Engineering, Raleigh, NC 27695-7533, USA
Received 21 January 2003; received in revised form 12 May 2003; accepted 4 June 2003
Abstract
Using the rate of flow method and the double power law function for basic creep of concrete,
an algorithm is developed for the time-dependent behavior of concrete-filled steel tube (CFT),
with or without the interface bond. The model adheres to geometric compatibility and static
equilibrium, and considers the effects of sealed concrete, multi-axial state of stresses, creep
Poisson’s ratio, stress redistribution, variable creep stress history, and creep failure of the
column. The model is verified against previous creep tests for bonded and unbonded speci-
mens. A study is then carried out on the practical design parameters that may affect creep of
CFT columns under service loads, or lead to their creep rupture at high levels of sustained
load. The study indicates that creep of CFT columns should be considered in the design,
however, with creep coefficients much lower than those prescribed in the current ACI. Creep
of CFT is shown to be a function of concrete mix, column geometry, and interface bond.
Therefore, a single ultimate creep coefficient cannot be used for all concrete mixes, column
geometries, and construction types. Bonded tubes curtail creep of concrete much more than
the equivalent unbonded ones, mainly because of the stress relaxation phenomenon, which is
more pronounced for smaller diameter-to-thickness ratios. For diameter-to-thickness ratios of
40 or less, bonded tubes are more durable in creep rupture than the equivalent unbonded ones.
Creep rupture life of 75 years is quite feasible in bonded CFT, with diameter-to-thi
您可能关注的文档
- chapter 6-Intermolecular Forces-2012,4,10.pdf
- chapter2xcalibur.pdf
- chapter 4 拼缀构词法.ppt
- chapter3-search.pdf
- Characteristics of Polymer Concrete Mixture Design of Experiments and Response Surface Method.pdf
- Characterization and Fine Mapping of a Necrotic Leaf Mutant in Maize.pdf
- Characterization nbyLEAFYandAGL15.pdf
- Characteristics of activated carbons prepared from pistachio-nut shells.pdf
- Characterization and Expression Analysis Of Six Chitinase From Microdera Punctipennis Low Tempe.pdf
- Characterisation of weathered clayey soils responsible for shallow landslides.pdf
文档评论(0)