RS Components 电工电料 PCB变压器 44200 使用说明.pdfVIP

RS Components 电工电料 PCB变压器 44200 使用说明.pdf

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
S R O T C U D N I MY RRA S ...Of course ! R E M R O F S N A R T TECHNICAL INFORMATION RATED PRIMARY VOLTAGE (V) This is the supply voltage assigned to the t ransformer by the manufact urer. RATED SECONDARY VOLTAGE (V) This is the secondary out put voltage assigned to the t ransformer when supplied with the rated primary voltage, frequency range, rated secondary current, all assigned by the manufact urer for the specified operating conditions of the t ransformer. RATED POWER (VA) The specified power levels in this catalogue are the secondary power levels, in other words, those available when the t ransformer is loaded. It is the product of the RMS rated secondary voltage by the RMS rated current. If the t ransformer has more than one out put winding, the rated power denotes the maximum sum of the products of RMS rated secondary voltage by the RMS rated secondary current, respectively. This rated power is defined for rated ambient temperat ure conditions. example P = 3,2 VA ta 70/ B The t ransformer can deliver 3.2VA at maximum ambient (70°C), the load consisting of a resistor load defined by R(load) = U(sec)2/ P (assigned U sec P values), heating does not exceed the relevant limit for Class B components used in this const ruction. NOTE : When the t ransformer is intended to supply DC voltage and current in conjunction with rectifiers and smoothing capacitors, the VA power required from the t ransformer is far higher than the U(DC) and I(DC) product. To help you to determine the t rue t ransformer power, our Technical Department is at your disposal. AMBIENT TEMPERATURE (ta) The maximum temperat ure at which the t ransformer may be operated continuously under nominal conditions of use. It is the air temperat ure measu- red close to the t ransformer after therma

您可能关注的文档

文档评论(0)

说明书资料库 + 关注
实名认证
文档贡献者

提供在线代找服务,有需求可咨询!

版权声明书
用户编号:7105131051000023

1亿VIP精品文档

相关文档