- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
Evaluation of Wall Designs that Control Airborne Sound Transmission墙的设计,控制空气中声传输的评价.doc
TECHNICAL REPORT EVALUATION OF WALL DESIGNS THAT CONTROL AIRBORNE SOUND TRANSMISSION Firm Ideas FIRM IDEAS May 1, 2003 Mike Parker, Manager of EBC Properties 1123 Parker Lane Austin, TX 78705 Dear Mr. Parker: The attached technical report contains Firm Ideas’ evaluation of wall designs that control airborne sound transmission. This report includes the descriptions of each wall design, the evaluation process, and the wall design that Firm Ideas recommends EBC Properties use in their new apartment complexes. We used the solution criteria established by EBC Properties and Firm Ideas to evaluate six wall designs: Single Stud Wall with Resilient Channel Single Stud Wall with Sound Deadening Board Staggered Stud Wall Staggered Stud Wall with Sound Deadening Board Double Stud Wall Double Stud Wall with Sound Deadening Board Firm Ideas recommends that EBC Properties use the Double Stud Wall in their new apartment complexes. First, the Double Stud Wall provides moderate performance with an STC value of 53 decibels. Second, the Double Stud Wall has a relatively low material cost of $11.98 per linear foot and a relatively low labor cost of $8.74 per linear foot. Finally, the Double Stud Wall can support the highest mountable object weight of 110 pounds per linear foot. This wall design best meets the needs of EBC Properties. Firm Ideas is available to answer any questions you may have concerning this report or the project in general. You can contact Firm Ideas at (512) 400-3333 or by email at engineers@. Sincerely, Jeffrey Hunt Project Engineer Evaluation of Wall Designs that Control Airborne Sound Transmission Prepared for EBC Properties Prepared by Jeff Hunt Firm Ideas May 1, 2003 Table of Contents List of Illustrations…………………………………………………………………………… i Executive Summary…………………………………………………………………………. ii Introduction…………………………………………………………………………………… 1 Background…………………………………………………………………………………… 1 Purpose, Scope, and Limitations……………………………………………………………… 1 Methodol
您可能关注的文档
- Models of models filtering and bias rings in depiction of knowledge 模型的滤波和知识描述偏置环模型.docx
- 基于jsp的空教室查询系统的设计与实现论文.doc
- 美式卖权订价之数值方法.doc
- Objective #4 Activities目的# 4活动.docx
- 2009年中医医院管理年活动检查评估细则.doc
- Site Nippondenso Kota Plant - World Technology Evaluation 现场电装亚植物世界技术评估.doc
- 北京市中医类别全科医师.doc
- 抗震设计规范修订简介.doc
- 上海市食品药品监管系统软课题研究指南.doc
- 22a Consultant Brief - Capital Development Guidelines22a顾问短暂资本发展的指导方针.doc
有哪些信誉好的足球投注网站
文档评论(0)