一起化工电气设备跳闸事故的剖析(Analysis of a chemical electrical equipment tripping accident).docVIP

一起化工电气设备跳闸事故的剖析(Analysis of a chemical electrical equipment tripping accident).doc

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
一起化工电气设备跳闸事故的剖析(Analysis of a chemical electrical equipment tripping accident)

一起化工电气设备跳闸事故的剖析(Analysis of a chemical electrical equipment tripping accident) This paper contributed by loukangbiao. Pdf document may at the WAP end of the browsing experience poor. Suggest you select TXT, or download the source file to the machine view. Technical exchange Analysis of Chemical Electrical Equipment trip accident Wei Hua Luo Sichuan Meifeng (4 seven, R Limited by Share Ltd, Sichuan Deyang 618000) 1 after the accident In January 30, 2007 18:oo, a synthetic ammonia plant of a chemical plant conversion section of a furnace fan (10kV high voltage asynchronous motor trip), due to the special nature of the production process of synthetic ammonia chemical plant, was forced to an emergency stop device. After 3min, the ammonia plant of 10kV high voltage power distribution room II busbar power line switch tripping, lokV autorestart switching, lokV II bus from the 10kVI bus power supply. At the same time, the distribution of ammonia plant room II bus power line switch and section II bus accident accident, outlet switch bus line switch 3 switches are low voltage overcurrent action. Low voltage BZT switching, low voltage low voltage busbar by section II I bus power supply, all power bus accident. The trip after the accident, the accident causes immediately find the chemical enterprise instrument workshop and technical personnel. After several hours of work, the ammonia recovery of power supply. The conditions, autorestart microcomputer protection device sends a signal to disconnect the II bus power line switch, delay 0.1s, 10kV autorestart automatic closing switch. (left) caused by 0kVII bus TV two side outlet switch trip: check on 10kV II bus TV loop, no grounding and short-circuit point, good insulation, then TV voltage switching parallel device for examination, but the normal input voltage, output voltage phase, open circuit board device has been burned, and a short-circuit fault phenomenon, through comprehensive analysis, TV two side outlet switch tripping is

您可能关注的文档

文档评论(0)

jgx3536 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:6111134150000003

1亿VIP精品文档

相关文档