框架结构软弱层的验算和操纵(国外英文资料).docVIP

框架结构软弱层的验算和操纵(国外英文资料).doc

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  4. 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  5. 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  6. 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  7. 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
框架结构软弱层的验算和操纵(国外英文资料)

框架结构薄弱层的验算和控制(国外英文资料) The examination and control of the weak layer of frame structure (the frame shear structure should remove the shear wall and then be flexible.) A control meaning: Avoid the easy occurrence of weak layer, if unavoidable take corresponding measures to strengthen B standard provisions High gauge 4.4.2, 5.1.14 rule, seismic design of high-rise building structure, the lateral stiffness is less than 70% of its on a layer of floor or less than 80% of its three layers in the lateral stiffness are average, or a floor vertical discontinuous component to resist lateral force, the weak layer standard values corresponding to the seismic action of seismic shear coefficient with the increasing of should be multiplied by 1.15. Gauge fan regulation: high gauge 4.4.3 and 5.1.14 rule, A level between the height of the high-rise building floor layer upon layer shear bearing capacity of structures to resist lateral force should not be less than its 80% of A layer of shear bearing capacity, should not be less than its on A layer of shear bearing capacity of 65%; The shear bearing capacity of the lateral force structure of the upper floors of the high-rise buildings should not be less than 75% of the shear capacity of the upper layer. Aseismic design of high-rise building structure, building structure layer upon layer between the bearing capacity of the structure to resist lateral force is less than 80%, its standard with weak layer corresponding to the seismic action in earthquake shear should increase multiplied by the coefficient of 1.15. C method and program implementation Weak layer method: judge by layer stiffness ratio Weak layer method two: according to the floor bearing capacity ratio is judged Weak layer method 3: the displacement Angle between the layer elastic-plastic layer is judged is judged by the stiffness of the layer Specification is required to clear the stiffness of the structure of the layer, weak in determining if a floor layer, the calculati

文档评论(0)

f8r9t5c + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

版权声明书
用户编号:8000054077000003

1亿VIP精品文档

相关文档