MINI MCR-SL-R-UI(-SP)

Description Resistance/potiposition transducer MINI MCR-SL-R-UI(-SP) ? PHOENIX CONTACT - 03/2008 Data Sheet INTERFACE The slim MINI MCR-SL-R-UI... potiposition transducer has a width of only 6.2 mm and converts potentiometer positions as a percentage to an analog standard signal. If the potenti- ometer range cannot be utilized to the full, an externally ac- cessible slide switch is used to set the upper and lower poti- position end values. The output signal between 0 and 100% is based on this fixed end value. The DIP switches are accessible on the side of the housing and allow the following parameters to be configured: – Output signal, – Automatic potentiometer detection, – Open circuit detection slider and – Fault evaluation type. Power (19.2 V DC to 30 V DC) can be supplied through con- nection terminals on the modules or in conjunction with the DIN rail connector. WARNING: Correct usage in potentially explosive areas The module is a category 3 item of electrical equipment. Follow the instructions provided here during instal- lation and observe the safety instructions. Make sure you always use the the latest documentation. It can be downloaded at . A conversion table is available on the Internet at /general/7000_en_00.pdf. This data sheet is valid for all products listed on the following page: Features – Configurable potiposition transducer – Output signal range can be configured using a DIP switch – Approval for Ex zone 2 (nA) – Can be supplied with screw or spring-cage connection 102807_en_05 MINI MCR-SL-R-UI(-SP) 102807_en_05 PHOENIX CONTACT 2 Description Type Order No. Pcs. Pkt. Resistance/potiposition transducer, Screw connection MINI MCR-SL-R-UI 2864095 1 Resistance/potiposition transducer, Spring-cage conn. MINI MCR-SL-R-UI-SP 2810256 1 Accessories Type Order No. Pcs. Pkt. DIN rail connector (T-BUS), 5-pos., for bridging the supply voltage, can be snapped onto NS 35/... DIN rails according to EN 60715 ME 6,2 TBUS-2 1,5/5-ST-3,81 GN 2869728 10 MINI M

文档评论(0)

l215322 + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档