Cooling Towers
If a chiller is used to provide chilled water for building air conditioning, then the heat energy that is absorbed through that process must be rejected. The two most common ways to reject thermal energy from the vapor compression process are either directly to the air or through a cooling tower. In a cooling tower, water is recirculated and evaporatively cooled through direct contact heat transfer with the ambient air. This cooled water can then be used to absorb and reject the thermal energy from the condenser of the chiller. The most common cooling tower used for HVAC applications is the mechanical draft cooling tower (Figure 4.2.13). The mechanical draft tower uses one or more fans to force air through the tower, a heat transfer media or fill that brings the recirculated water into contact with the air, a water basin (sump) to collect the recirculated water, and a water distribution system to ensure even dispersal of the water into the tower fill.
Figure 4.2.14 shows the relationship between the recirculating water and air as they interact in a counterflow cooling tower. The evaporative cooling process involves simultaneous heat and mass transfer as the water comes into contact with the atmospheric air. Ideally, the water distribution system causes the water to splash or atomize into smaller droplets, increasing the surface area of water available for heat transfer. The approach to the wet-bulb is a commonly used indicator of tower size and performance. It is defined as the temperature difference between the cooling water leaving the tower and the wet-bulb of the air entering the tower. Theoretically, the water being recirculated in a tower could reach the wetbulb temperature, but this does not occur in actual tower operations.
FIGURE 4.2.14
您可能关注的文档
最近下载
- 系统性红斑狼疮诊治进展PPT课件.pptx
- 2025年eVTOL航线规划与空域管理关键技术分析报告.docx
- 2025年城市低空交通发展报告:eVTOL航线规划与空域管理.docx
- 低空出行新时代:2025年eVTOL航线设计与空域管理策略研究.docx
- 2025广东春季高考英语试卷.doc VIP
- 广东省2025届春季高考学业水平考试语文试卷(四)(含答案).docx VIP
- 标准图集-22S804 矩形钢筋混凝土蓄水池.pdf VIP
- 2025年广东省高中学业水平考试春季高考数学试题(含答案解析).docx VIP
- 招标代理服务服务方案.doc VIP
- VR技术对博物馆游客游览满意度的提升研究论文.doc VIP
文档评论(0)