- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ABB ACS800 multidrive 培训讲义(中)
ACS800 multidriveintroduction Connectivity Maximum I/O configuration with multi block Redundancy Built-in redundancy through parallel connected modules Each module is a complete three-phase inverter Enables running with partial load if one module fails Provides for higher drive availability and greater process uptime Unique in drives - not available in previous generation ABB drives ACS800 R8i parallel connection concept New PPCS Branching Unit APBU-44 Includes parallel connection support for 2…12 inverter modules. Basic board supports 1…4 inverter and with APEB-84C option board up to 12. APBU-44 includes fast data logger. Data can be uploaded via PPCS link to be analysed. This function can be used to find faulty component in the main circuit. ACS800 Parallel connected modules Other new and modified diagnostics messages (X = inverter number 1…12) (Y = phase: U, V, W)- CUR UNBAL x Current unbalance - OVERCURR x Over current - SC INV x y Short circuit- TEMPD INV x Temperature difference between the inverter modules with alarm / fault- INV DISABLED DC supply for inverter module has been opened- ACS TEMP x y Inverter module over temperature Reduced Run Function If inverter module is broken: 1. Power off! 2. Isolate broken inverter module from the main circuit 3. Power on! 4. Drive diagnostics indicates that configuration is not original by indicating INT CONFIG fault 5. If user wants to continue run with limited current, number of existing inverter modules must be typed to parameter INT CONFIG USER 6. Reset the fault - PPCS link is reconfigured automatically - maximum current is limited in relation of actual inverter configuration and inverter nominal current 7. Start the drive! Assembly of the R8i module Assembly of the R8i module Assembly of the R8i module Assembly of the R8i module Assembly of the R8i module Assembly of the R8i module List of options for Drive units
文档评论(0)