Carrier开利Gemini® Packaged Heat Pump Air-Handling Unit with EcoBlue™ Technology 40RFQ 40RFQ Guide Specifications, 2,400 to 3,000 Nominal cfm, 6 to 10 Nominal Tons说明书用户手册.doc

Carrier开利Gemini® Packaged Heat Pump Air-Handling Unit with EcoBlue™ Technology 40RFQ 40RFQ Guide Specifications, 2,400 to 3,000 Nominal cfm, 6 to 10 Nominal Tons说明书用户手册.doc

  1. 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
  2. 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  3. 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
查看更多
PAGE 1 PAGE 1 Split System Heat Pump Indoor Unit (Air-Handling Unit) with Puron? Refrigerant HVAC Guide Specifications Size Range: 2,400 to 3,000 cfm, Nominal Airflow 6 to 10 Tons, Nominal Cooling Carrier Model Numbers: 40RFQ*07-12 General System Description Indoor, packaged air-handling unit for use in commercial heat pump split systems. Unit shall have a multi-position design and shall be capable of horizontal or vertical installation on a floor or in a ceiling, with or without ductwork. (Only vertical units are to be applied without ductwork.) Unit shall function as the indoor component of an air-to-air electric heat pump system. Unit must be designed with a Puron? (R-410A) refrigerant circuit with a matching air-cooled condensing unit 38AUQ, for matched systems approved by the manufacturer. Quality Assurance All coils shall be designed and tested in accordance with ASHRAE 15 Safety Code for Mechanical Refrigeration, latest edition. Unit shall be constructed in accordance with ETL and ETL, Canada, standards and shall carry the ETL and ETL, Canada, labels. Unit insulation and adhesive shall comply with NFPA-90A requirements for flame spread and smoke generation. Insulation shall be treated with an immobilized antimicrobial agent to inhibit the growth of bacteria and fungi on the insulation as proven by tests in accordance with ASTM standards G21 and 22 (U.S.A.). Unit shall be manufactured in a facility registered to the ISO 9001 manufacturing quality standard. Direct-expansion coils shall be leak tested at 150?psig and pressure tested at 650 psig and qualified to UL burst test at 1980 psig. Delivery and Storage Units shall be stored and handled per manufacturers recommendation. Products Equipment Base Unit: Indoor mounted, draw-thru, packaged air-handling unit that can be used in a suspended horizontal configuration or a vertical configuration. Unit shall consist of a direct drive vane axial fan and motor assembly, pre-wired fan motor controller, factory-ins

文档评论(0)

R的文档库 + 关注
实名认证
内容提供者

相近型号说明书可通用,具体看说明书包括型号

版权声明书
用户编号:7060103150000024

1亿VIP精品文档

相关文档