复印机维修)(Copier maintenance)).docVIP

  1. 1、本文档共12页,可阅读全部内容。
  2. 2、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。
  3. 3、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载
  4. 4、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
  5. 5、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
  6. 6、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们
  7. 7、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
  8. 8、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
复印机维修)(Copier maintenance)).doc

复印机维修)(Copier maintenance)) Clear key - insert key - 0 key - insert key - master code - start key - sub code - start key (copy record input value) Example: main code, sub code content 14 remove faults other than U2 15 clear U2 faults 247 drum count cleaning Sharpe AR1818 H, 4 flashing fault code elimination method are as follows: Press the C key, pause / insert key, 0 key, pause / insert key, then all lights disappear, then press 1, 4 keys, and then press the copy key. Be accomplished。 1818 villain solution 20-1 is counting..24-7 is off the drum drum off time counting. The operation is as follows.C- plugged into -C- -20- -1- copy copy key button to complete. Press the CA button. I was in Shanghai. 02128520401 When the villain appears: change the toner cartridge and scraper. Before you replace it, you must clean the optical unit and replace it. After you replace it, use code 20-1. Perform clearing the 24-7 count of the drum during execution, so that you can pull the maintenance mode into the method: C- insert the -0 insert key 1818 missing powder The leakage in the front cover may be empty or full of waste powder, is for compact and leakage in the transfer drum may be not the problem of the carrier or SHARP 1818 shows how to remove F5! Is F502? If yes, first clean the optical and inspection whiteboard, if not well, replace the CCD harness SHARP 1818, carrier leakage Difficult miscellaneous diseases You and I have a master of 1818, printed 140 thousand, leakage carrier, are recovered in the waste box, I have a new carrier, and missing a lot, the last by the leakage, hope to have high guidance one or two, 1, drum assembly fails, or you change the carrier when the gear turn the wrong direction, you put the developer around the carrier clean, and then look at the development of the Yellow chip is deformed SHARP 1818 now appears H4??? Fixing is warm and low. If 14 is not clear, try it with 16. Ive also met before AR-1818 appear H2, not normal boot, you master can help me

文档评论(0)

zhangningclb + 关注
实名认证
文档贡献者

该用户很懒,什么也没介绍

1亿VIP精品文档

相关文档