- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
ASM焊线机F15 功能菜单说明
Function 15 Process Service menu EFO Control EFO Delay Setting of the EFO time delay before the EFO sparks. EFO Setting EFO Box Type (STD/Heavy) Select the EFO box type according to the ff: STD For 0.6 – 1.5 mil wire size application Heavy For 1.5 – 3.0 mil wire size application EFO Control EFO Current (mA) The amount of current flow to melt the gold wire. Larger Current creates harder FAB and lower current creates softer ball Auto Calc EFO Time No/Yes Yes is auto calculation of EFO time and current based on the FAB size selected No is manual selection of EFO time and current EFO Control EFO Time (μs) Determines the time on how long the EFO will spark. Longer time will provide bigger FAB EFO Gap Warning Volt EFO breakdown voltage checking on the threshold voltage. If the Breakdown voltage is greater than the EFO Gap Voltage, the machine will give ‘ the EFO Gap Wide’ warning for short tail. EFO Control EFO Control Mode Cap/FAB/FAB2 Capillary - Machine will be automatically calculate the FAB depending on the capillary geometry. In this case user need to load/key in the capillary data. FAB - manual key in of FAB Value FAB2 – used for stand off ball control Skip Die Control Ink Size (Radius) Size of the ink pattern represented in pixels Skip Bad Die Supports matrix and hybrid programs Whenever the die quality is reject, the current die will be skipped without further checking the ink. No teaching procedure for this function is required. Just Die PR dependent. Function cannot be used together with ‘Skip Missing Die’ function. Skip Die Control Skip Missing Die VLL Before Check Ink Yes – VLL will be done before checking the ink mark Skip missing die Yes – skip missing die Skip Die Control Skip Missing Die Supports the HYBRID, MATRIX and Single unit programs. Take note that if this function is applied to Hybrid program, make sure that a unique pattern and ink_check position are taught on the upper right unit. Skip Die Control Ski
您可能关注的文档
最近下载
- 个人信息保护影响评估报告(模板).docx VIP
- 必威体育精装版主题教育新中国史知识竞赛试题精编(100题含答案).pdf VIP
- 丰田第十二代皇冠介绍.pdf
- 2025“才聚齐鲁成就未来”山东黄金集团井下技能工人招聘2000人备考题库及答案解析.docx VIP
- 剑桥少儿英语三级官方公布的真题样题.pdf VIP
- 动火许可证(一级、二级、三级动火许可证).doc VIP
- 2025年辽宁省公务员省考《行测》联考真题(含答案).docx VIP
- 看拼音写词语_人教版二年级下册(新)各单元全册及答案.pdf VIP
- (2025年)国企会计岗位笔试试题及答案解析.docx VIP
- 院感知识培训.pptx VIP
文档评论(0)