- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
2,4,6-三氯苯酚合成文摘
2,4,6-三氯苯酚 部分合成文摘 1.Microfluidic device capable of sensing ultrafast chemiluminescence ByKim, Young-Teck; Ko, Seok Oh; Lee, Ji Hoon FromTalanta (2009), 78(3), 998-1003. Language: English, Database: CAPLUS Based on the principle of liq. core waveguide, a novel microfluidic device with micro-scale detection window capable of sensing flashlight emitted from rapid 1,1-oxalyldi-4-methylimidazole (OD4MI) chemiluminescence (CL) reaction was fabricated. Light emitted from OD4MI CL reaction occurring in the micro-dimensional pentagonal detection window (length of each line segment: 900.0 μm, depth: 50.0 μm) of the microfluidic device with two inlets and one outlet was so bright that it was possible to take an image every 1/30 s at the optimal focusing distance (60 cm) using a com. digital camera. Peaks obtained using a flow injection anal. (FIA) system with the micro-scale detection window and OD4MI CL detection show excellent resoln. and reproducibility without any band-broadening obsd. in anal. devices having addnl. reaction channel(s) to measure light generated from slow CL reaction. Maximum height (H max) and area (A) of peak, reproducibility and sensitivity obsd. in the FIA system with the microfluidic device and OD4MI CL detection depends on (1) the mole ratio between bis(2,4,6-trichlorophenyl) oxalate and 4-Me imidazole yielding OD4MI, (2) the flow rate to mix OD4MI, H2O2 and 1-AP in the detection window of the microfluidic device, and (3) H2O2 concn. The authors obtained linear calibration curves with wide dynamic ranges using H max and A. The detection limit of 1-AP detd. with H max and A was ≥0.05 fmole/injection (signal/background = 3.0). Substances Reactions Citing Full Text Link 0 Comments 0 Tags 2.1,1-Oxalyldisodiumbenzoate derivatives, method for preparation thereof and chemiluminescent composition containing the same ByLee, Ji Hoon; Kim, Young Teck; Hong, Young-Shick; Suh, Hee Sang FromPCT Int. Appl. (2008), WO 2008062957 A1 Language: Engli
文档评论(0)