- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
接地安装标准(Grounding installation standard)
接地安装标准(Grounding installation standard) Grounding pole installation standard Author: anonymous release date: 2008-5-12 18:23:21 (read 2613 times) Key words: grounding installation Installation requirements and skills of grounding electrodes Key words: grounding electrode installation Earthing equipment shall be made of steel, and the conductor section of grounding device shall comply with the requirements of thermal stability and mechanical strength, but shall not be smaller than the specifications below. Category specifications and units On the ground underground indoor outdoor AC current circuit DC current loop Round steel diameter (mm) Six Eight Ten Twelve Flat steel Cross section (mm2) Thickness (mm) Sixty Three One hundred Four One hundred Four One hundred Six Angle steel thickness (mm) Two Two point five Four Six Thickness of steel pipe wall (mm) Two point five Two point five Three point five Four point five Two. The buried depth of the top of the grounding body shall not be less than 0.6 meters, and the angle steel and the steel pipe grounding body shall be vertically configured. In addition to the ground, the lead line of the grounding body shall be treated as antiseptic; when the galvanized steel bar is used, the bolt joint of the lead line shall be painted with anticorrosive paint. Three, in order to reduce the shielding effect of the adjacent grounding body, the spacing of the vertical grounding body should not be less than two times of its length, and the spacing of the horizontal grounding body should be less than 5 meters according to the design requirements. Four. The distance between the grounding body and the building should not be less than 1.5m. Five, grounding wire should prevent mechanical damage and chemical corrosion, grounding wire through the wall, through the hole, through the steel pipe or other strong protective sleeve. Six. The grounding line shall be connected with the grounding grid at least two different points. Seven each earthing pa
您可能关注的文档
- 循环系统2(Circulatory system 2).doc
- 循环系统疾病的诊断方法(Diagnostic methods for diseases of circulatory system).doc
- 循环队列和杨辉三角(Cyclic queue and Yang Hui triangle).doc
- 微电子技术专业(Microelectronics technology major).doc
- 循环经济之牛粪种植双孢菇(Circulation economy cow manure planting Agaricus bisporus).doc
- 微博上那些浸透人心的语录(Those soaked sayings on micro-blog).doc
- 微积分模拟试题一(Calculus simulation questions).doc
- 微积分部分练习(Calculus part practice).doc
- 微絮凝_超滤组合工艺处理低浊度海水(Micro flocculation _ ultrafiltration combined process for treatment of low turbidity seawater).doc
- 微积分的定位`要求`变化及其缘由(The positioning of calculus requires ` changes' and their causes).doc
- 接着谈马克思主义中的上班族就是无产阶级的概念(Then, the concept of office worker in Marx's theory is the concept of proletariat).doc
- 接触器铭牌说明(Contact plate specification).doc
- 控制与保护开关电器(Control and protection switch apparatus).doc
- 控制台修复系统命令(Console repair system command).doc
- 控制别人电脑(高手必看)(Control other people's computer (master must see)).doc
- 控制保护开关说明(Control switch description).doc
- 控制性详细规划中的土地使用兼容性控制的探究管理(Research and management of land use compatibility control in regulatory detailed planning).doc
- 控制网页中层的隐藏与显示(Controlling the hide and display of web pages).doc
- 控制面板内的所有运行命令包括添加删除应用程序等(All commands in the control panel include add, delete, application, and so on).doc
- 控制面板 命令(Control panel command).doc
文档评论(0)