- 1、有哪些信誉好的足球投注网站(book118)网站文档一经付费(服务费),不意味着购买了该文档的版权,仅供个人/单位学习、研究之用,不得用于商业用途,未经授权,严禁复制、发行、汇编、翻译或者网络传播等,侵权必究。。
- 2、本站所有内容均由合作方或网友上传,本站不对文档的完整性、权威性及其观点立场正确性做任何保证或承诺!文档内容仅供研究参考,付费前请自行鉴别。如您付费,意味着您自己接受本站规则且自行承担风险,本站不退款、不进行额外附加服务;查看《如何避免下载的几个坑》。如果您已付费下载过本站文档,您可以点击 这里二次下载。
- 3、如文档侵犯商业秘密、侵犯著作权、侵犯人身权等,请点击“版权申诉”(推荐),也可以打举报电话:400-050-0827(电话支持时间:9:00-18:30)。
- 4、该文档为VIP文档,如果想要下载,成为VIP会员后,下载免费。
- 5、成为VIP后,下载本文档将扣除1次下载权益。下载后,不支持退款、换文档。如有疑问请联系我们。
- 6、成为VIP后,您将拥有八大权益,权益包括:VIP文档下载权益、阅读免打扰、文档格式转换、高级专利检索、专属身份标志、高级客服、多端互通、版权登记。
- 7、VIP文档为合作方或网友上传,每下载1次, 网站将根据用户上传文档的质量评分、类型等,对文档贡献者给予高额补贴、流量扶持。如果你也想贡献VIP文档。上传文档
查看更多
fibercoupling的概要1
Fiber coupler This article describes a commercial fiber coupler, which couples two pieces of Corning SMF-28e Fiber using SUSS MicroOptics FC-Q-250 microlens arrays: The manufacturers data is as follows: Single Mode Fiber, Corning SMF-28e1 Numerical Aperture 0.14 Core Diameter 8.3 μm Mode Field Diameter @1.31 μ 9.2 ± 0.4 μm Microlens Array, SUSS MicroOptics SMO399920 2 Substrate material Fused Silica Substrate thickness 0.9 mm Internal Transmission 0.99 Lens Diameter 240 μm Lens Pitch 250 μm Radius of Curvature 330 μm Conic Constant 0 Numerical Aperture 0.17 The file single mode coupler.zmx in the attached zip file (which can be downloaded from the last page of this article) shows how to implement this system. Please note the following: The object/lens and lens/image distance has been set by hand to 0.1 mm as this is approximately the right value. This number is to be computed by the optimization routine later A pick-up solve is used to make the final lens-image thickness the same as the initial object-lens image. Since the lenses and fibers are identical (within manufacturing tolerances), the optical system should work either way round, and should therefore by symmmetric The separation of the two lenses is set to 2 mm, as this is the experimental distance used. Again, this distance will be computed by rigorous optimization later The system aperture is set using float by stop size on the rear face of the first lens. This means that the system aperture is set by the physical aperture of the lens. The fiber mode we propagate through this system can be clipped by this physical aperture. In this case, the fiber mode is significantly smaller than the physical aperture Be wary of the multiple definitions of the term numerical aperture. It may use the sine of the marginal ray angle, the sine of the angle at which the intensity has fallen to 1/e2 (both definitions are used in different calculations in Zemax, as we shall see) or
文档评论(0)