The basic components of a smart toilet are as follows:
1) computer plate (2) water tank device (3) cleaning device 4) drying device 5) pressurization unit 6) water unit 7) remote control 8) deodorization device 9) flip device 10) solenoid valve device 11) transformer 12) LED display 13) MP3 device 14) seat 15) infrared device
Intelligent toilet common fault and judgement processing
1) failure: nothing
Check part (power outlet, leak protection plug, power button, installation strip contact, transformer primary, panel, computer board)
Exclusion method: does the power socket have electricity? If you have, do you see if the key to the plug is shown? Is the power supply pressed? Is the cover and the installation bar in good contact? Does the transformer have 7V output? Is the panel short-circuited? If the above is normal, the computer board is bad
2) failure: water is not hot (other normal)
Check part (remote control, water tank heating tube, water temperature sensor, hot fuse wire, computer board)
Rule out: is the remote control temperature set? The wait for 10 minutes, no hot, please remove the measuring tank resistance is about 92 ohms around on both ends of the hotline, and test whether there are about 92 ohm resistor on both ends of the heating tube, without the fuse bad, measuring at the ends of the temperature sensor resistance (25 k to 80 k) as normal, if all the bad computer board, such as in the tank, change detection is normal, after water have been heating is computer board bad to change together.
3) failure: the seat temperature is not heated (other normal)
Check part (remote control, seat coil heater, temperature sensor, computer board, connector)
Excluded methods: set up with the remote control heating state (the wait 10 minutes) without heating, please remove the seat hotline measurement on both ends of about 960 + / - 50 ohm resistance value, without heating wire op